Filter Results By:

Products

Applications

Manufacturers

Showing results: 31 - 41 of 41 items found.

  • Test and Measurement/ EMC

    Antenna Research Associates

    ARA offers both outdoor far field range services and indoor anechoic chambers at all of its locations. Outdoor ranges vary from 5,000 ft, 1250 ft, to 300 ft. ARA has forklifts, crane services, and man-lifts to suit your antenna size and weights. Complete RF measurement instrumentation is available for conducting all standard tests up to 40 GHz. RF testing is conducted in accordance with ANS / IEEE Std. 149-1979 "Standard Test Procedures for Antennas."

  • Calibration

    Seibersdorf Labor GmbH

    During the recent years we have made scientific investigations regarding calibration procedures, which have been published and integrated in the European and International standards. The calibration of antennas and field probes in Seibersdorf is done on the reference open area test site, in three different TEM-Cells and in the fully anechoic chamber. The open area test site is one of the best in Europe. Since 1996 we are the accredited calibration laboratory according to Akkreditierung Austria 0612 for antennas and field probes.

  • Near Field Probes

    Com-Power Corporation

    A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.

  • Calibration

    Kiwa Dare

    Calibrations of electronic equipment is one of the activities that Kiwa Dare offers to its clients. these calibrations are under accreditation in the field of electrical quantities. Besides calibrations in the field of DC current, DC voltage and low frequency (test and measuring) equipment, Kiwa Dare is specialized in calibrating high frequency measuring equipment and in particular EMC equipment in a frequency range of (DC) 40 GHz. New the site validation calibrations whereby Kiwa Dare can calibrate shielded rooms (Faraday room) and anechoic chambers under accreditation.

  • Production Line Acoustic Test Chamber

    PLATC - Listen Inc

    The Production Line Acoustic Test Chamber from GRAS is designed for quick and qualified acoustic test of cell phones, tablet PCs, Bluetooth speaker systems etc., including frequency response, THD, Rub & Buzz and microphone test using optional sound source. The chamber has a number of connections for injecting test and control signals to the test object (DUT).Benefits include:Repeatable testing and reliable dataEasy open/close for quick and safe change of DUTFlexible test jig for easy adjustment to new DUTFlexible microphone mounting for both front/backside speakers as well as edge-mounted speakersHigh quality, high sensitive 1/4” CCP measurementmicrophone included (G.R.A.S. 46BL)Individually calibrated frequency response** Compared to reference measurement in anechoic room

  • Automotive EMC Testing

    EMC Technologies Pty Ltd

    Having been assessed by Ford Detroit’s EMC expert, we are Australia’s only Ford (and NATA) accredited automotive EMC test laboratory. Others have tried, but none have succeeded. Ford does not accept reports from EMC labs that are not on the Ford list of accredited labs. The scope ranges from component to complete vehicle level EMC testing for Australian and overseas manufacturers. We also have a fully dedicated CISPR 25 Electronic Sub Assembly (ESA) chamber, another large CISPR 25 anechoic chamber for vehicle testing or susceptibility levels in excess of 500V/m. We possess a vast array of specific automotive EMC test equipment such as BCI’s, tri-plate’s, and striplines for susceptibility and emissions testing to meet the most stringent automotive EMC requirements. Our Australian and overseas customers use our labs because they know that our reports will be accepted and will not be questioned.

  • Automotive Radar Testers

    Rohde & Schwarz GmbH & Co. KG

    Rohde & Schwarz provides automotive manufacturers, components suppliers and test houses with innovative, cutting-edge solutions which bring realistic test scenarios from the road to the lab and production line.Our range of solutions include a signal generator-based target simulator, a radome & bumper tester and an anechoic automotive radar test chamber allowing for over-the-air (OTA) testing. These solutions are at the heart of the development of advanced driver assistance systems (ADAS) with its safety-critical features such as emergency braking. Using T&M solutions by Rohde & Schwarz enables a thorough testing of chipsets, sensors and modules at each phase from development and conformance to production.

  • RSE Wireless EMC Spurious Emission

    TS8996 - Rohde & Schwarz GmbH & Co. KG

    The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.

  • Broadband Antenna

    Vivaldi - DVTest Inc.

    The dbDIRECT Broadband Antenna features a broad frequency range of operation, high gain, small form factor and directional radiation pattern, making it highly attractive for widespread use in test and measurement of emerging wireless technology devices and radars. Contrary to conventional Vivaldi antennas limited to operating only at higher frequencies, the dbDIRECT Broadband Antenna design is optimized to operate at a frequency as low as 700 MHz up to 6 GHz. This lightweight and compact antenna design provides excellent matching over a broad frequency range.The antenna is designed to be placed in a DVTEST's portable anechoic chamber such as the dbSAFE enclosures for OTA (Over the Air) testing of DUTs. The antennas can be mounted in fixed positions to facilitate repeatable results. When used in conjunction with a rotary positioning mechanism, customers are able to detect the highest point of power sensitivity for enhanced accuracy and repeatability in measurements. In this configuration, both the antennas and DUTs can be positioned in order to facilitate the measurement.

  • Hand-In Type Electromagnetic Anechoic Box (Shield Box)

    MY3720 - MICRONIX

    Suitable for weak electric field resistance test, out-of-service test or digital forensics for smart phone, tablet terminal or mobile PC ! !DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.

  • Hand-In Type Electromagnetic Anechoic Box (Shield Box)

    MY3710HS - MICRONIX

    Higher shielding performance than MY371080dB. Suitable for weak electric field resistance test, out-of-service test or digital forensics for mobile phone, smart phone or tablet terminal! DUT can be operated directly with bare hands while placing it in the box and looking at the inside from the shield window.